Part III

System Messages

14 Active Sensing

Format

Message Format: FEH

Send

This message is never sent.

Receive

Once this message is received, the Active Sensing mode is entered. If no MIDI message is received for a specified amount of time, voices being sounded by the Instrument’s sound source are released, the controller is reset, and the Active Sensing mode is exited.

15 System Exclusive Message

Format

Message Format:

....F0H

F7H

The Instrument sends and receives standard universal system exclusive messages, and system exclusive messages that have Instrument-specific formats.

15.1Universal Realtime System Exclusive Message

Format

Message Format:

F0H 7FH

....F7H

15.1.1Master Volume

Format

Message Format: F0H 7FH 7FH 04H 01H llH mmH F7H

ll:Value LSB

mm:Value MSB

Send

This message is never sent.

Receive

Receipt changes the Master Volume parameter. Note that the Master Volume parameter cannot be changed with an Instrument operation.

23