17 Parameter Transfer

There are two parameter operations: Individual Parameter Transfer and Individual Parameter Request.

A single session is concluded only when this Instrument returns an IPS (Individual Parameter Send) in response to an IPR (Individual Parameter Request) from an external device, or when an external device or this Instrument spontaneously sends an IPS. If this Instrument received an IPS, the value of the applicable parameter is changed.

Depending on the function of a parameter, Individual Parameter Send may be used to issue a command to the Instrument or Individual Parameter Request may be used to check Instrument status information.

17.1Two-way Communication

17.1.1Example : Data send in response to send request to the Instrument

Data Receiver

 

Data Sender

 

Operation

IPR

 

Send Request

 

IPS

 

Data Transfer

17.2One-way Communication

17.2.1Example : Data send to Instrument from external source

Data Sender

 

Data Receiver

 

Operation

 

IPS

 

Data Transfer

17.2.2Example : Data send resulting from Instrument operation

Data Receiver

 

Data Sender

 

Operation

 

IPS

 

Data Transfer

33