Part-1 QUICK START OPERATION

9. Basic Operation after Basic Programming

Note:

Whenever an error is generated, the input figures reset to 0. All printout samples are journal images and the header (date, time and consecutive no.) are eliminated from the samples.

OperationPrintout

Mode Switch

REG CAL X Z

OFF

RF

PGM

9-1 Open the drawer without a sale

m

08-01-2010

08:55

 

REG

0001

 

NS

••••••••••

— No Sale Symbol

9-2 Basic operation

Example

Unit Price

$1.00

$2.00

$0.30

Quantity

1

1

1

Dept.

1

10

15

Cash

 

 

 

Amount

 

$5.00

 

tendered

 

 

 

Z??

Unit Price Department 1

jX??

Department 10

jjC?

Department 15

08-01-2010

09:00

REG

0002

DEPT01

•1.00— Department No./Unit Price

DEPT10

•2.00

DEPT15

•0.30

TOTAL

•3.30— Subtotal

CASH

•5.00— Cash Amount Tendered

CHANGE

•1.70— Change Amount Due

B??p

Cash amount tendered

Departments 6 through 10, 11 through 15, 16 through 20 can also be regis-

tered in combination with the jand , , , or keys, respec- tively. The jkey should be entered just before entering unit price manually.

9-3 Multiple registra- tion of the same items

Example

Unit Price

$1.00

$1.35

Quantity

2

3

Dept.

1

2

Z??

Department 1

Unit Price

Ch

Quantity

Multiple key

ZCB

08-01-2010

09:05

 

REG

0003

 

DEPT01

•1.00

 

DEPT01

•1.00— Repeat

3 X

@1.35

— Sales Quantity/ Unit Price

DEPT02

•4.05

CASH

•6.05

 

 

 

 

p

Note that repeat registration can be used with unit prices up to 6 digits long.

9-4 Charge sales

 

Z??

Example

 

 

 

 

X??

 

 

 

 

 

C??

Unit Price

$1.00

$2.00

 

$3.00

Quantity

1

1

 

1

 

Dept.

1

2

 

1

u

 

 

 

 

 

Charge key

08-01-2010

09:10

 

REG

0004

 

DEPT01

•1.00

 

DEPT02

•2.00

 

DEPT01

•3.00

 

CHARGE

•6.00— Charge Sales

 

 

 

You cannot perform the amount tendered operation using the ukey.

E

14

Page 14
Image 14
Casio SE-S10 Basic Operation after Basic Programming, Basic operation, Multiple registra- tion of the same items, Zcb