Troubleshooting

Troubleshooting

The coffee machine does not

The machine is not fully back in its

Push the coffee machine back

switch on

housing.

fully.

 

 

 

 

There is a problem with the electricity

Check that the mains supply

 

supply.

has not been switched off.

 

 

Check that the fuse in the spur

 

 

has not blown.

 

 

 

The coffee will not dispense or

The coffee grind is too fine.

Adjust the grind to be coarser.

dispenses only in slow drips

 

 

There is not enough water in the water

Fill the water tank or check

 

 

tank

there is no fault with the mains

 

 

water supply.

 

 

 

 

The internal pipes are obstructed

 

 

 

 

The coffee dispenses too fast and is

The coffee grind is too coarse.

Adjust the grind to be finer.

not creamy

 

 

The coffee is too old

Replace the coffee beans with

 

 

 

fresh beans

 

 

 

 

Coffee blend

Change the coffee beans for

 

 

those appropriate for use.

 

 

 

The pump makes a loud noise when

There is not enough water in the water

Fill the water tank or check

dispensing coffee

tank (non-mains water supply only)

there is no fault with the mains

 

 

water supply.

 

 

 

 

The coffee grind is too coarse so the

Adjust the grind to be finer.

 

pressure in the filter holder is too low.

 

 

 

 

Milk froth does not form

 

Check the flow of steam is

 

 

suitable

 

 

 

The coffee machine is equipped with an auto-diagnostic system to recognise and advise on how to deal with faults. These alerts will show on the display.

Machine

Display shows

Solution

on/off

 

 

 

 

 

OFF

CLOSE TAP

Close the steam control knob

 

 

 

OFF

DESCALING

Descale the coffee machine

 

 

 

ON

TECHNICAL SERVICE

Before calling CDA Customer Care, first try pulling the coffee machine out and

 

 

pushing it back in fully.

 

 

 

ON

WATER PRESSURE

Check the water tank is full and then open the water dispensing tap, letting

 

 

water out of the steam nozzle until the display stops flashing. This allows the

 

 

system to refill.

 

 

 

ON

GRINDER

Check the grinder for any foreign bodies (e.g. stones or impurities). Fully turn

 

 

the grind adjustment control knob anti-clockwise then remove any impurities

 

 

by running the grinder for a few seconds. Once this is complete, return the

 

 

grind adjustment control knob to its previous position.

 

 

 