CDA EVCK4 Mains Electricity Connection, Double Pole Switched Fused Spur Outlet, USE A 3 AMP FUSE

Models: EVCK4

1 12
Download 12 pages 24.06 Kb
Page 6
Image 6
Mains Electricity Connection

Mains Electricity Connection

THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE.

We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.

The wires in the mains lead of this appliance are coloured in accordance with the following code:

BLUE = NEUTRAL, BROWN = LIVE.

As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the terminals connecting to the fused spur, proceed as follows:

The wire which is coloured blue must be connected to the terminal marked N (Neutral), or coloured black.

The wire which is coloured brown must be connected to the terminal marked L (Live), or coloured red.

DOUBLE POLE SWITCHED

FUSED SPUR OUTLET

USE A 3 AMP FUSE

NOTE: USE A 3A FUSE

Assembly and electrical connection should be carried out by competent personnel.

When installing this product we recommend you seek the help of another individual.

IMPORTANT: THIS APPLIANCE IS A CLASS II APPLIANCE (DOUBLE INSULATED) AND IS NOT INTENDED TO BE EARTHED. DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR.

Do not mount the isolation switch behind the chimney section. It is a requirement that you must be able to isolate the extractor from the mains electrical supply after installation.

This appliance is intended to be connected to the mains electrical supply by means of an isolation switch and fused spur and is intended to be protected by a 3A fuse. The use of a 13A fuse can cause damage to the internal wiring in the event of a fault, and may also invalidate the warranty.

Electrical Information

Mains electrical voltage: 230 – 240Vac, 50Hz

Total rated power consumption:

290W

Troubleshooting

If your extractor is not working:

1.Check that the mains supply has not been switched off.

2.Check that the fuse in the spur has not blown.

5

Page 6
Image 6
CDA EVCK4 Mains Electricity Connection, Double Pole Switched Fused Spur Outlet, USE A 3 AMP FUSE, NOTE: USE A 3A FUSE