Mounting your extractor

6.When used with a CDA hob, the extractor is required to be 650mm above the hotplates. Measure the height of the ceiling and then the hotplate height from the floor. The length of the support sections should be calculated as follows: -

Length of support = Ceiling height – (149 + 650 + Hotplate height)

Note that if the exact height cannot be set, use the frame position corresponding to the next highest one.

7.Fit the lower section (B) to the upper section (C) at the correct height and secure in position using the supplied screws (G)

8.Refit (If required) and secure the motor body to the lower section and secure with the supplied screws.

Fig. 10

Fig. 11

8

Page 9
Image 9
CDA EVCK4 manual Mounting your extractor