CDA HCC360 manual Repairs, Feeder Cable Section, 230 L N, Replacing The Power Supply Cable

Models: HCC360

1 21
Download 21 pages 58.22 Kb
Page 19
Image 19
REPAIRS

A

Fig. 8.1

F

Fig. 8.2

REPAIRS

REPLACING THE POWER SUPPLY CABLE

(for 2 electrical plates and vitroceramic models)

Turn the cooktop over and unhook the terminal board cover by inserting a screwdriver into the two hooks “A” (fig. 8.1).

Open the cable gland by unscrewing screw “F” (fig. 8.2), unscrew the terminal screws and remove the cable.

The new supply cable, of suitable type and section, is connected to the terminal board following the diagram fig. 8.3.

REPLACING THE POWER SUPPLY CABLE (for gas models)

-The supply cable must be replaced with a cable of the same type.

-The electrical cable must be connected to the terminal board following the diagrams of fig. 8.4.

FEEDER CABLE SECTION

COOKING HOB GAS

type “H05V2V2-F”

resistance to temperatures of 90°C

230 V~

3 x 0,75 mm2

230 V REPLACING THE POWER SUPPLY CABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

N (L 2)

 

 

 

 

 

 

 

PE

Fig. 8.3

230 V

L (for 2 electrical plates and vitroceramic models)REPLACING THE POWER SUPPLY CABLE (for gas models)FEEDER CABLE SECTION N

Fig. 8.4

COOKING HOB ELECTRIC HOTPLATES

The external diameter of the supply cable must not be more than 9 mm.

tipo “H05RR-F”

230 V~

3 x 1,50 mm2

COOKING HOB VITROCERAMIC

The external diameter of the supply cable must not be more than 9 mm.

type “H05RR-F”

230 V~

3 x 1,50 mm2

38

Page 19
Image 19
CDA HCC360 Repairs, Feeder Cable Section, 230 L N, Replacing The Power Supply Cable, Cooking Hob Gas, type “H05V2V2-F”