CDA HCN610 manual Mains Electricity Connection, Warning! this appliance must be earthed

Models: HCN610

1 16
Download 16 pages 48.71 Kb
Page 12
Image 12
Mains Electricity Connection

Mains Electricity Connection

Warning! this appliance must be earthed

We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.

This appliance is intended to be connected to fixed wiring and is not suitable for connection to a 13A plug or 13A supply.

This appliance is intended to be connected to fixed wiring by a double pole switch, having a contact separation of at least 3mm in all poles. The switch must be positioned no further than 2m from the appliance.

This appliance is supplied with a 3 core mains cable; the wires are in accordance with the following code:

Green & Yellow = Earth

Blue = Neutral

Brown = Live

Please note:

The mains cable must only be replaced by a qualified electrician or service engineer and must be of equivalent or better rating (i.e. 2.5mm2, HO5V2V2-F).

This appliance is intended to be connected to the mains supply with a cable of cross section area 2.5 mm2. A larger cable will not fit the terminal connections.

The marking of the current rating of the fuse or circuit breaker protecting this appliance should be marked on the socket outlet.

Assembly and electrical connection should be carried out by specialised personnel.

When installing this product we recommend you seek the help of another individual.

 

Black - grey

 

 

 

Green / yellow

 

Green / yellow

Blue

 

 

Blue

 

Brown

Brown

N L

or

N L

Use a 32A circuit breaker or fuse

Fig.7

Page 12
Image 12
CDA HCN610 manual Mains Electricity Connection, Warning! this appliance must be earthed