WARNING:

MACHINE WARRANTY IS VOID IF MACHINE IS CONNECTED TO ANY VOLTAGE OTHER THAN 120 VOLTS. (EXPORT UNITS SHOULD BE CONNECTED TO 220 VOLTS)

** INSTALLATION INSTRUCTIONS **

NOTE: A SEPARATE CIRCUIT SHOULD BE SUPPLIED FOR EACH OF THESE BREWERS WITH A 15 AMP CIRCUIT BREAKER OR FUSE. CHECK LOCAL CODES FOR COMPLIANCE IN INSTALLATION.

MANUAL POUROVER MODELS

Are not equipped with water inlet connections

AUTOMATIC WITH POUROVER BACKUP

Are equipped with a ¼" flare water inlet fitting which is located in the back of the unit.

WATER INLET CONNECTION:

HIGHLY RECOMMENDED: A water shut-off valve and a water filter, preferably a combination charcoal / phosphate filter, to remove odors and inhibit lime and scale build up in the machine. Note: In areas with extremely hard water, a water softener must be installed in order to prevent malfunctioning of the equipment and in order not to void the warranty.

This equipment is to be installed to comply with the applicable federal, state, or local plumbing codes having jurisdiction. In addition:

1.A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for cleaning underneath.

2.An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.

CAUTION:

DO NOT CONNECT TO POWER SOURCE UNTIL AFTER PRIMING

These brewers are equipped with a rear Toggle Switch which controls the power to the tank heater. Toggle Switch must be in the down or “OFF” position until step (3) is completed.

** PRIMING INSTRUCTIONS**