Output Volume Setup

Output Volume Setup

a. Turn the output volume setup switch ON (1) and press the PROG (setup) button.

 

 

 

LED

Setup Button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Keys

b.The output LEDs should be lit, indicating the machine is in setup mode.

c.To configure key 1, press the key 1 button, which should light LED 1 and switch off all other LEDs. Once desired setup parameters have been set, press key 1 again to confirm and exit key 1 setup.

d.At this point, LED 1 should be off and LED's 2, 3 and 4 should be lit.

e.Repeat steps (b) through (d) to set up keys 2, 3 and 4, respectively.

f.The left set(s) of keys will mirror the value settings in the set of keys to its immediate right. Repeat steps (b) through (e) if different output volumes are desired for different cup compartments.

g.After completing setup, turn the output volume setup switch OFF (1) to return the machine to normal operational mode.

4-5 Automatic Reverse Flushing

a.Press any key simultaneously to start automatic reverse flushing. Keys 2-4 in the control panel will start flashing and start automatic reverse flushing from the right output system to the left.

b.The default is 10 cleaning cycles.

c.Flush the second output system after flushing the first output system. Or press the 3rd key to skip to the next output system, System will stop automatically after finish all the reverse flushing.

4-6 Stopping the Machine

a.After cleaning the machine, remove all liquids and solid matter from the water tray.

b.Turn off the power (turn power switch to position 0).

c.Open steam knob to release steam flow. Do not place any liquid under the steam tube during this process in to avoid system contamination.

5.Cleaning and Maintenance

5-1 Cleaning the Machine Body

Wipe machine exterior with soft, slightly dampened cloth daily before starting operations.