adjustment slot and turn it
THERMOSTAT: To adjust the temperature of the water in the urn, turn the thermostat knob to “10”and remove the knob without moving the thermostat shaft. Place narrow bladed screwdriver (1/8”) into the hollow thermostat shaft and engage center adjustment screw. When thermometer reading approaches 198F slowly turn the adjustment screw clockwise until the burner goes out. Turning the screw
MAINTENANCE TIPS
WATER CONDITION: Remove and clean spray head cap and spray head disc
OUTSIDE SERVICE: Should you require help, contact the factory, your factory representative, or your local service company.
FOR QUALIFIED SERVICE PERSONNEL ONLY
When servicing of unit is required, contact a qualified service agency.
CAUTION: DO NOT TURN ON THERMOSTAT BEFORE ALL PRIMING INSTRUCTIONS ARE COMPLETED.
•WATER FROM COLD WATER SUPPLY LINE DOES NOT ENTER URN
1.Check water supply to
2.Check fuse () on the front panel and replace it if necessary.
3.If steps 1 & 2 are in order, remove fuse and lift control box door.
4.Remove two screws from timer panel and remove timer exposing terminal strip and electrical wiring.
5.Replace fuse.
6.Place wire jumper across terminals () and () on terminal board (). If water enters urn, float switch is inoperative and should be replaced (see par10). If water does not enter urn, then solenoid valve () or small relay () is not functioning. To check solenoid valve, disconnect leads from the coil and apply 115V power. If solenoid operates replace relay.
7