1 11
Download 11 pages 26.29 Kb
Page 9
Image 9
Manual background

3.Open the control box and disconnect the two pump wires from the quick disconnect terminals.

4.Loosen union fittings on pump and remove pump from urn.

5.Replace pump and follow priming instruction.

NOTE: Pump and motor assembly is factory lubricated for the life of the pump.

TIMER SOLID-STATE

Depress BREW button, hold for approximately 10 seconds, and then release. If water flows from spray head when button is depressed and stops flowing after button is released, then timer is faulty and should be replaced. No water from spray head when button is depressed, indicates BREW button is fault and must be replaced.

AGITATOR

OPERATION: The agitator pump circuit is programmed to operate when the BREW button is pushed. Upon completion of the pump cycle, the agitator pump will pump air through the manifold into the coffee gauge glasses and into the coffee liner. The completed cycle will take approximately 20 second. The agitator may be operated independently of the brewing cycle, if the agitator button is depressed.

MAITENANCE: The air pump is capable of delivering enough air for proper blending. However if enough agitation is not present, check flexible tubing on top of gauge glasses and fittings, for possible air leaks. If air pump does not operate on completion of brewing cycle or when agitation button is depressed, replace air pump or solid state agitator timer (black box).

BURNER MAITENANCE

The two main burners can be removed by first removing the base cover panel and unfastening the burner ends. The main burners should be cleaned both inside the venturi portion and on the outside using a soft bristle brush. The main burners must be into the same position before removal. Once a year, a qualified service agency should be contacted to inspect the appliance for safe and proper operation.

SAFETY PILOT:

Remove pilot adjustment cap on the gas valve and turn adjustment screw to provide properly sized flame (3/4 inch long).

Replace the cap.

PILOT ADJUSTMENT CAP