Celestron VMC30SB-1, VMH30SB-1 manual Indoor unit installation

Models: VMH30SB-1 VMC30SB-1

1 29
Download 29 pages 49.81 Kb
Page 16
Image 16

Installation

Wrap the insulation material around the connecting portion.

1.Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap.

2.Wrap the area which accommodates the rear piping housing section with vinyl tape.

3.Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section.

Plastic bands Insulation material

Connection

Indoor

unit piping

pipe

 

Vinyl tape

Wrap with vinyl tape

(wide)

 

 

Pipe

 

Vinyl tape(narrow)

Connecting cable

 

 

Pipe

Drain hose

Vinyl tape(narrow)

 

 

Wrap with

 

vinyl tape(wide)

Reroute the pipings and the drain hose across the back of the chassis.

Piping for

passage through

piping hole

Indoor unit installation

1.Remove the spacer.

2.Ensure that the hooks are properly seated on the installation plate by moving it left and right.

3.Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

Connecting cable

Drain hose

16Room Air Conditioner

Page 16