LEAK TESTING THE VALVE, HOSE AND REGULATOR ASSEMBLY

1.Turn all grill control knobs to OFF.

2.Ensure that the regulator is tightly connected to LP cylinder.

3.Completely open LP cylinder valve by turning hand wheel counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a leak at the connection. Correct before proceeding.

4.Brush soapy solution onto hose and regulator and all connections from the LP tank to the main and side burner manifold.

5.If “growing” bubbles appear, there is a leak. Close LP cylinder valve immediately and re-tighten connections. If leaks cannot be stopped do not try to repair. Call for replacement parts. Order new parts by providing the serial number, model number, name and part number of items required (see parts list) to a CENTRO Customer Care Agent 1-877-707-5463.

6.Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.

WARNING

For all new, at home, natural gas connections please contact a certified gas technician to install your natural gas barbecue.

FOR NATURAL GAS MODELS (if applicable)

All Centro Natural Gas Barbecues come equipped with a 10’ or 12’ Natural Gas hose with a quick connect socket connection. This will allow you to attach your Barbecue to your residential gas line.

To Connect

1.Push back the sleeve on the Quick Connect socket and insert plug and release the sleeve as shown.

2.Push the two pieces together until the sleeve snaps forward, to lock the plug in the socket.

To Disconnect

1.Push sleeve back and pull the plug out.

Testing For Gas Leaks

Before attempting to operate this Grill:

Always confirm that all burner control knobs are in the OFF position.

Always connect the gas supply hose first, open lid and then open the gas shutoff valve.

ºAlways use a brush or spray bottle to apply a 50/50 solution of liquid soap and water to all connection points, to test for gas leaks. Never use a match or open flame for that purpose.

ºAlways look for bubbles to appear, as the appearance of bubbles will indicate a gas leak.

º Always turn off the gas immediately and tighten the connection, if you find that a leak has been detected.

ºBefore lighting the grill, always repeat this procedure until no further gas leaks are found.

ºIf a leak cannot be stopped, do not attempt to light the grill. Always contact a certified Natural Gas technician for assistance or the Centro Customer Care Hotline for assistance. 1-888-707-5463.

5

Page 8
Image 8
Centro 03122008 EJ warranty Leak Testing the VALVE, Hose and Regulator Assembly, To Connect, To Disconnect