Resolving BURNER Performance Issues

PROBLEM

IDENTIFYING THE CAUSE:

 

 

Burner will not light (with igniter

• Low or out of propane

or match)

• Cylinder or the gas supply valve is turned off

 

• Positive connection has not been made between the tank and the regulator.

 

Regulator will not allow fuel in the line

 

• Burner port holes or venturi tubes are blocked

 

• Venturi tubes are not properly seated over valve orifices

 

• The Flow Limiting Device in the regulator has been activated

 

 

Burner lights with match but not with

• Loose Electrode Wire connection

igniter (NO SPARK)

• Broken electrode – ceramic casing around electrode damaged

 

• Poor ground – igniter module connection not assembled properly

 

• Battery Damaged or dead.

 

• Faulty igniter

 

 

Fire at control knob and control panel

• Burner port holes, Venturi tubes, and/or gas jets are blocked

= Flash Fire

• Burner is improperly seated over gas jet

 

 

Yellow smoky flames

• Blocked Venturi tubes

 

• Excess cooking salts on burner

 

 

Flame blows out on LOW

• High Wind condition – Adjust the placement of BBQ to shield from wind

 

• Propane is running low

 

• Burner improperly seated on gas jet

 

• Flame Tamers (heat plates) are not in position

 

• Flow limiting device in the regulator has been activated

 

• NATURAL GAS MODELS: Installation issues related to incorrect size supply line

 

installed and /or Water Column supply is not adequate for a BBQ BTU rating of

 

this BBQ. Do not use a longer Natural Gas hose than is supplied with your BBQ.

 

 

Burner does not get hot enough

• BBQ needs to be preheated for 10 minutes with a closed lid. Ambient tempera-

 

tures will affect the performance of your BBQ. Always keep lid closed in colder

 

temperatures.

 

• Flow limiting device in regulator has been activated. See section, what is the

 

flow limiting device?

 

• NATURAL GAS MODELS: Installation issues related to incorrect size supply line

 

installed and /or Water Column supply is not adequate for a BBQ BTU rating of

 

this BBQ. Do not use a longer Natural Gas hose than is supplied with your BBQ.

 

 

Low or incomplete flame (assuming

• Proper start up and shut down procedure not followed. Flow limiting device has

burners and Venturi tubes are free and

been activated and requires resetting

clear of blockages)

• Positive connection not made between tank and manifold.

 

• Positive Vapour lock at coupling nut/LP cylinder connection not made. Discon-

 

nect hose and regulator from LP Cylinder and reconnect correctly.

 

• Flame Tamers (heat plates) are missing or not in position

 

• NATURAL GAS MODELS: Installation issues related to incorrect size supply line

 

installed and /or Water Column supply is not adequate for a BBQ BTU rating of

 

this BBQ. Do not use a longer Natural Gas hose than is supplied with your BBQ.

 

 

Too much heat/ Excessive flare up

• Excessive fat in meat

 

• Grease collection plate and grease cup need to be cleaned

 

• Cooking system including flame tamers and cooking grates have a build up of

 

grease that must be removed

 

• Lower casting of the BBQ is clogged with grease

 

• Must reduce cooking temperature according to the type of foods being cooked.

 

 