INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of the door at a minimum height of 5 feet where small children cannot reach, and away from moving parts of the door and door hardware. If installing into drywall (Fig. 1), drill 5/32" holes and use anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Fig. 2). NOTE: After installation, a green indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct).

1.Strip 1/4" of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to 2 and white/red wire to 1 (Fig. 3).

2.Remove white cover by gently pushing both thumbs against upper corners of cover on back side of door control (Fig. 4). Fasten with 6ABx1-1/4"self-tapping screws (standard installation) or 6-32x1" machine screws (into gang box) as follows:

Drill and install bottom screw, allowing 1//8" to protrude above wall surface.

Position bottom of door control on screw head and slide down to secure. Adjust screw for snug fit.

Install top screw with care to avoid

cracking plastic housing. Do not overtighten.

Insert bottom tabs and snap on cover. (To remove cover after mounting, gently pry at top with paper clip or small flat head screwdriver.)

3.(Standard installation only) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit.

4.Connect bell wire to the opener terminal screws as follows: white to 2 and white/red to 1. (Fig. 5).

5.Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in a prominent location on inside of garage door.

NOTE: DO NOT connect the power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned. See Safety Reversing Sensor Instructions beginning on page 17.

WARNING

To prevent possible serious injury or death from electrocution:

Be sure power is not connected before installing door control.

Connect only to 24 VOLT low voltage wires.

To prevent possible serious injury or death from a closing garage door:

Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet, and away from all moving parts of door.

Never permit children to operate or play with door control push buttons or remote control transmitters.

Activate door only when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.

Always keep garage door in sight until completely closed. Never permit anyone to cross path of closing garage door.

HARDWARE SHOWN ACTUAL SIZE

 

6AB x 1-1/4" Screw

 

Insulated

 

 

 

(standard installation)

 

Staples

 

 

 

 

6-32 x 1" Screw

 

 

 

 

 

 

 

(pre-wired installation)

 

Dry Wall Anchors

 

 

Figure 1

STANDARD

 

Figure 2

 

 

 

 

INSTALLATION

 

PRE-WIRED INSTALLATION

 

 

 

 

 

 

 

 

 

Single

 

 

 

 

 

 

Gang Box

 

 

LOCK

 

 

 

 

 

 

 

 

LIGHT

 

LOCK

 

 

 

 

 

 

 

 

 

 

 

 

To Replace

 

 

LIGHT

 

 

 

 

 

 

 

24 Volt

 

Insert Bottom Tabs First

To Replace

 

Bell Wire

 

 

 

Insert Bottom Tabs First

 

 

 

 

 

 

 

Figure 3

MULTI-FUNCTION

 

Figure 4

 

 

 

 

 

 

DOOR CONTROL (BACK)

 

 

 

 

 

 

Top Mounting Hole

 

REMOVE COVER

 

 

 

 

 

 

 

 

 

 

 

 

Terminal

 

 

 

 

 

 

 

 

Screws

 

 

 

 

 

 

RED WHT

 

 

 

 

 

 

 

1

2

 

 

RED WHT

 

 

 

 

 

 

 

1

2

 

 

 

 

 

Bell Wire

 

 

 

 

 

 

 

 

Bottom Mounting Hole

 

 

 

 

 

Figure 5

Bell Wire

Opener

 

 

 

 

 

 

Terminal Screws

 

 

 

 

 

 

 

 

Push

 

 

 

 

 

 

 

 

Bar

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

 

 

 

 

 

 

9

1

9

1

 

 

 

 

 

7

3

7

3

 

 

 

 

 

5

 

5

 

 

 

 

 

 

KG

 

KG

 

LOCK

 

 

 

 

 

 

 

 

LIGHT

 

BACK PANEL

 

 

 

 

 

 

 

 

 

 

 

Lock

Light Button

 

 

 

 

 

 

Button

 

 

 

 

 

 