MOUNTING AND WIRING THE SAFETYREVERSING SENSORS

Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten safety reversing sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5).

Finger tighten the wing nuts.

Figure 5

Wing Nut 1/4"-20

Carriage Bolt

1/4"-20x1/2"

Lens

Run the wires from both safety reversing sensors to the opener. Use insulated staples to secure wire to wall and ceiling.

Strip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener quick-connect terminals: white to white and white/black to grey (Figure 6).

ALIGNING THE SAFETY REVERSING SENSORS

Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct.

The sending eye amber indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required.

Loosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place.

Loosen the receiving eye wing nut and adjust the safety reversing sensor until it receives the sender’s beam. When the green indicator light glows steadily, tighten the wing nut.

TROUBLESHOOTING THE SAFETY

REVERSING SENSORS

1.If the sending eye indicator light does not glow steadily after installation, check for:

Electric power to the opener.

A short in the white or white/black wires. These can occur at staples, or at opener connections.

Incorrect wiring between safety reversing sensors and opener.

A broken wire.

2.If the sending eye indicator light glows steadily but the receiving eye indicator light doesn't:

Check alignment.

Check for an open wire to the receiving eye.

3.If the receiving eye indicator light is dim, realign either sensor.

NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The opener lights will blink 10 times. (If bulbs are not installed, 10 clicks can be heard.) See page 13.

Figure 6

To CableTension Monitor

Bell Wire

Motor unit

Bell Wire

To Power

Door Lock

WHT/RED

WHT

To Control Console

Connect Wire to

Quick-Connect

Terminals

Sensor

Connections

WHT/BLK

WHT

Power Door Lock

Quick-Connect Terminals

Safety Reversing Sensor

 

 

 

Invisible Light Beam

Safety R

eversing Sens

or

Protection Area

16