INSTALLATION STEP 6

Install the Control Console

Locate control console within sight of door, at a minimum height of 5' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 1).

CAUTION: Continuous exposure of the control console to temperatures below -22° F (-30° C) may damage the LCD screen.

NOTE: The functional temperature range of the control console is between -20° C (-4° F) and 50° C (122° F). Scroll speed of display is slower at lower temperatures although the control console remains fully functional.

SPECIAL NOTE: Only one 398LM can be connected to each garage door opener. If additional wall controls are desired to operate the same garage door opener, it is recommended to use model 378LM wireless wall control as the secondary control console.

1. Strip 7/16" (11 mm) of insulation from one end of

bell wire and connect to the two screw terminals

on back of control console by color: white wire to

the white (2) and white/red wire to the red (1)

(Figure 2).

2. Remove push bar cover by gently prying at the

lower/middle portion of the cover with a small

flat-head screwdriver. Fasten with 6AB x 1-1/4"

WARNING

To prevent possible SERIOUS INJURY or DEATH from electrocution:

Be sure power is not connected BEFORE installing door control.

Connect ONLY to 24 VOLT low voltage wires.

To prevent possible SERIOUS INJURY or DEATH from a closing garage door:

Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m) and away from ALL moving parts of door.

NEVER permit children to operate or play with door control push buttons or remote control transmitters.

Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.

ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.

HARDWARE SHOWN ACTUAL SIZE

Screw 6ABx1-1/4"

Insulated

(std installation)

Staples

Screw 6-32x1"

 

(pre-wired)

Drywall Anchors

Figure 1

 

STANDARD WALL MOUNT

PRE-WIRED INSTALLATION

self-tapping screws (drywall installation) or

6-32 x 1" machine screws (into gang box) as

follows:

• Install bottom screw, allowing 1/8" (3 mm) to

protrude above wall surface.

To Replace

Insert Top

Tabs First

ON OFF

24 Volt Bell Wire

To Replace

Insert Top

Tabs First

• Position bottom of control console on screw head

and slide down to secure. Adjust screw for snug

fit.

Push Bar Cover

LOCK

Figure 2

LIGHT

Detector

Switch

Push Bar

Cover

LOCK

LIGHT

 

 

Detector ON Switch OFF

• Drill and install top screw with care to avoid

cracking plastic housing. Do NOT overtighten.

• Replace cover by inserting top tabs first and then

snap cover in place.

3. (For standard installations ONLY) Run bell wire

up wall and across ceiling to motor unit. Use

insulated staples to secure wire in several places.

Do NOT pierce wire with a staple, creating a short

or open circuit.

4. Strip 7/16" (11 mm) of insulation from end of bell

wire. Connect bell wire to the quick-connect

terminals on the motor unit: white to white and

white/red to red (Figure 3).

NOTE: If you have any trouble with the operation of the buttons, loosen the top mounting screw.

2-Conductor Bell Wire

RW

12

(BACK VIEW)

Figure 3

Top

Mounting

Hole

Door

Control

Terminal

Screws

Bottom

Mounting

Hole

Door Control

Connections

To release wire, push in tab with screwdriver tip

NOTE: DO NOT connect the power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned. See Safety Reversing Sensor Instructions beginning on page 16.

Red White Grey

7/16" (11 mm)

Strip wire 7/16" (11 mm)

13