01-G1014 Field Wiring Diagram

32

FIELD WIRING

IT IS IMPORTANT TO READ ALL SAFETY RULES INCLUDED IN THE INSTALLATION MANUAL BEFORE BEGINNING INSTALLATION. FAILURE TO COMPLY WITH THE SAFETY INSTRUCTIONS MAY RESULT IN SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE.

CONTROL WIRING

 

LINE VOLTAGE SUPPLY

 

 

 

 

MANUAL

ON

 

SWITCH

 

OPEN

 

 

SEE

 

OFF

 

115V

NOTE #1

 

 

SEE NOTE #2

OUTLET

SENSING EDGE

SEE

 

 

NOTE #3

 

 

OPEN BUTTON

OR OTHER

OPEN CONTROL

CLOSE BUTTON

SEE NOTE #2

ELECTRICAL CABINET

WARNING

115V

 

OPEN

HOLD OPEN

1 PHASE

 

 

ACCESSORIES

 

LOOP

LOOP

 

 

 

(SEE NOTE #5)

(SEE NOTE #5)

 

 

 

 

INCOMING

 

(0.2A MAX)

 

 

 

 

 

 

LINE

 

 

 

 

LOOP WIRE CONNECTIONS FOR

 

 

 

 

 

FACTORY SUPPLIED (PLUG-IN)

 

 

 

 

 

DETECTORS ONLY

 

 

LOOP DETECTORS BY OTHERS

 

 

RADIO CONTROL

 

 

 

 

 

 

 

 

CONNECTIONS FOR LOOP DETECTORS

 

 

 

 

 

 

 

 

CONNECTIONS FOR STANDARD

 

NOT SUPPLIED BY THE FACTORY

 

 

 

3-WIRE 24 VAC RADIO CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESENCE CONTACT OF

 

PRESENCE CONTACT OF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOOP TO OPEN

 

LOOP TO HOLD OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RADIO CONTROL WILL OPEN GATE

 

 

LOOP WIRES AND POWER FOR LOOP DETECTORS

 

 

 

 

 

AND REVERSE IF CLOSING. IT WILL

 

 

SHOULD BE DIRECTLY WIRED TO DETECTOR ITSELF.

 

 

 

 

 

 

NOT STOP OR CLOSE THE GATE.

 

REFER TO INSTRUCTIONS ACCOMPANYING DETECTOR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1)REMOVE THIS JUMPER TO CAUSE GATE ARM TO CLOSE IMMEDIATELY WHENEVER IT IS OPENED, UNLESS A VEHICLE IS ON THE HOLD OPEN LOOP. IF THIS JUMPER IS NOT REMOVED, ARM WILL REMAIN OPEN UNTIL A VEHICLE ENTERS AND EXITS THE HOLD OPEN LOOP.

2)ADD JUMPER FROM TERMINAL #8 TO #9 WHENEVER CLOSE BUTTON IS USED. DO NOT USE WITH HOLD OPEN LOOP.

3)115V UTILITY OUTLET (4 AMP MAX.) PROVIDED ON 115V MODELS ONLY.

4)SEE REVERSE SIDE FOR INTERNAL OPERATOR WIRING.

5)DO NOT CONNECT INPUT POWER LINES TO L1 & L2 TERMINALS. POWER LINES MUST BE CONNECTED TO THE POWER SWITCH. DRAWING NO.: 01-G1014

Doc 01-G0674 Rev E