CARE OF YOUR OPENER
LIMIT AND FORCE ADJUSTMENTS:Weather conditions may cause |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
some minor changes in door | INCREASE TRAVEL | |||||||
operation requiring some re- | ||||||||
adjustments, particularly during | DOWN | UP | ||||||
|
|
|
|
|
|
| ||
the first year of operation. | LIMIT CONTROLS | |||||||
Pages 27 and 28 refer to the limit |
| (Left Panel) | ||||||
and force adjustments. Only a |
|
|
|
|
|
|
| |
screwdriver is required. Follow |
|
|
|
|
|
|
|
|
the instructions carefully. |
|
|
|
|
|
|
|
|
Repeat the safety reverse test |
|
|
|
|
|
|
|
|
(Adjustment Step 3, page 29) |
|
|
|
|
|
|
|
|
after any adjustment of limits |
| FORCE CONTROLS | ||||||
or force. | (Back Panel) |
To prevent possible SERIOUS INJURY or DEATH:
•NEVER allow small children near batteries.
•If battery is swallowed, immediately notify doctor. To reduce risk of fire, explosion or chemical burn:
•Replace ONLY with 3V2032 coin batteries.
•DO NOT recharge, disassemble, heat above 100° C (212° F) or incinerate.
The lithium battery should |
|
produce power for up | Battery |
to 5 years. To replace | positive |
battery, use the visor clip | side up (+) |
or screwdriver blade to pry |
|
open the case as shown. |
|
Insert battery positive side |
|
up (+). |
|
Dispose of old battery properly. |
|
•Manually operate door. If it is unbalanced or binding, call a trained door systems technician.
•Check to be sure door opens & closes fully. Adjust limits and/or force if necessary (see pages 27 and 28).
•Repeat the safety reverse test. Make any necessary adjustments (see Adjustment Step 3).
Two Times a Year•Check chain tension. Disconnect trolley first. Adjust if necessary (see page 11).
Every Year•Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
32