CARE OF YOUR OPENER
THE REMOTE CONTROL BATTERY
LIMIT AND FORCE ADJUSTMENTS:

Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation.

Pages 27 and 28 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully.

INCREASE TRAVEL

DOWN UP

LIMIT CONTROLS

(Left panel)

9

1

9

1

7

3

7

3

5

 

 

5

KgKg

To prevent possible SERIOUS INJURY or DEATH:

NEVER allow small children near batteries.

If battery is swallowed, immediately notify doctor.

To reduce risk of fire, explosion or chemical burn:

Replace ONLY with 3V2032 coin batteries.

DO NOT recharge, disassemble, heat above 212°F (100°C) or incinerate.

Repeat the safety reverse test (Adjustment Step 3, page 29) after any adjustment of limits or force.

MAINTENANCE SCHEDULE

FORCE CONTROLS

(Back panel)

The lithium battery should produce power for up to 5 years.

To replace battery, use the visor clip or screwdriver blade to pry open the case as shown. Insert battery positive

Battery positive

side up (+)

Once a Month

Manually operate door. If it is unbalanced or binding, call a trained door systems technician.

Check to be sure door opens & closes fully. Adjust limits and/or force if necessary. (See pages 27 and 28)

Repeat the safety reverse test. Make any necessary adjustments. (See Adjustment Step 3)

Twice a Year

Check chain tension. Disconnect trolley first. Adjust if necessary. (See page 11)

Once a Year

Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.

side up (+).

Dispose of old battery

properly. Replace the battery with only 3V2032 coin cell batteries.

NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.

Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.