Diagnostics
Located On
Motor Unit
LED or
Diagnostic
LED “Learn”
Button
Safety Reversing Sensor
Installed
Safety Reversing
Sensor
Your garage door opener is programmed with
it has found a potential issue. Consult Diagnostic Chart below.
Diagnostic Chart
| 1 FLASH | Symptom: One or both of the indicator lights on the safety reversing sensors | ||
| ||||
|
| do not glow steady. | ||
Safety reversing sensors | ||||
• Inspect sensor wires for a short (staple in wire), correct wiring polarity | ||||
wire open (broken or | ||||
| (black/white wires reversed), broken or disconnected wires, replace/attach | |||
disconnected). |
| |||
| as needed. | |||
| OR |
| ||
| • Disconnect all wires from back of motor unit. | |||
| 2 FLASHES | • | Remove sensors from brackets and shorten sensor wires to | |
| ||||
|
| from back each of sensor. | ||
|
|
| ||
Safety reversing sensors | • | Reattach sending eye to motor unit using shortened wires. If sending eye | ||
wire shorted or black/white |
| indicator light glows steadily, attach the receiving eye. | ||
wire reversed. |
| |||
• Align sensors, if the indicator lights glow replace the wires for the sensors. If | ||||
|
| |||
| 3 FLASHES |
| the sensor indicator lights do not light, replace the safety sensors. | |
|
| |||
| Symptom: LED is not lit on door control. | |||
|
| • Inspect door control/wires for a short (staple in wire), replace as needed. | ||
Door control or wire shorted. | ||||
|
| |||
|
| • Disconnect wires at door control, touch wires together. If motor unit activates, | ||
|
|
| replace door control. | |
|
| • If motor unit does not activate, disconnect door control wires from motor unit. | ||
|
|
| Momentarily short across red and white terminals with jumper wire. If motor | |
|
|
| unit activates, replace door control wires. | |
| 4 FLASHES | Symptom: Sending indicator light glows steadily, receiving indicator light is | ||
|
| dim or flashing. | ||
Safety reversing sensors | ||||
• Realign receiving eye sensor, clean lens and secure brackets. | ||||
slightly misaligned | ||||
(dim or flashing LED). | • Verify door track is firmly secured to wall and does not move. | |||
| 5 FLASHES | Symptom: Motor has overheated; the motor unit does not operate; | ||
|
| RPM Sensor = Short travel | ||
Motor overheated or possible | • Unplug unit to reset. Try to operate motor unit, check diagnostic code. | |||
RPM sensor failure. Unplug | • If it is still flashing 5 times and motor unit moves | |||
to reset. | ||||
| RPM sensor. | |||
|
|
| ||
|
| • | If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and | |
| 6 FLASHES |
| retry. If motor unit still will not operate replace logic board. | |
| Symptom: Motor unit doesn’t operate. | |||
|
| • Replace logic board because motor rarely fails. | ||
Motor Circuit Failure. | ||||
|
| |||
Replace Receiver Logic |
|
| ||
Board. |
| 34 | ||
|
|
|