A D J U S T M E N T

ACCESSORY WIRING

Field Wiring Terminals 9 & 5 - Obstruction Open (Edge/Photo Eye Input)

Edge Input: See Programming Section

This input will reverse an opening gate to the close limit. Activating this input when the gate is closing will have no effect. NOTE: If upon reversal a second separate obstruction is detected (gate edge or RPM sensor), gate will stop and alarm.

Photo Eye Input: See Programming Section

This input will pause an opening gate. Once the input (photo eye) is cleared, the gate continues to open. Activating this input when the gate is closing will have no effect.

Field Wiring Terminals 10 & 5 - Obstruction Close (Edge/Photo Eye Input)

Edge Input: See Programming Section

This input will reverse a closing gate to the open limit. When reaching the open limit the Timer to-Close, if enabled, will be disabled until another command is given. Activating this input when the gate is closing will have no effect. NOTE: If upon reversal a second separate obstruction is detected (gate edge or RPM sensor), gate will stop and alarm.

Photo Eye Input: See Programming Section

This input will reverse a closing gate to the open limit. This input will not affect the Timer-to-Close. Activating this input when the gate is closing will have no effect.

Field Wiring Terminals 3 & 5 - Stop/Reset Control Input

These terminals are intended for use with a single stop/reset button or the stop control of a three-button station that is installed within line of site of the gate. This input functions to stop the gate or to reset the gate after an entrapment fault. NOTE: This input uses a normally closed circuit and the operator will not run until a stop control is installed.

J1 Terminals 4 & 5 - Hard Close Control Input

These terminals are intended for use only with the close control of a three-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to close. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye.

J1 Terminals 7 & 5 - Hard Open Control Input

These terminals are intended for use only with the open control of a three-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to open. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo eye.

OBSTRUCTION OPEN (EDGE/PHOTO EYE INPUT)

5 8 9 10 11 12

OBSTRUCTION CLOSE (EDGE/PHOTO EYE INPUT)

5 8 9 10 11 12

STOP/RESET BUTTON WIRING

 

 

 

 

 

OPEN

R1

R2

R3

R4

3

5

 

 

 

 

 

CLOSE

 

 

 

 

 

STOP

STOP

HARD CLOSE CONTROL INPUT

 

 

 

 

 

 

 

 

 

OPEN

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16

 

 

 

 

 

 

 

 

 

CLOSE

 

 

 

 

 

 

 

 

 

CLOSE

 

 

 

 

 

 

 

 

 

STOP

HARD OPEN CONTROL INPUT

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16

OPEN

OPEN

CLOSE

STOP

22