A D J U S T M E N T

CONTROL BOARD PROGRAMMING AND FEATURES

MOTOR LEARN FUNCTION (FORCE PROFILE)

This function is preprogrammed at factory. If either board or motor is replaced, the controller will need to be programmed to “LEARN” the specific motor RPM profile of your operator. Switch “S3” is provided for this. This is important for accurate force control. Failure to do so may result in improper and unsafe operation.

To learn the motor:

NOTE: Motor Learn must be performed in stand alone mode.

1.The operator must remain attached to the gate throughout the entire process.

2.Press the motor learn button. The yellow LED should start to flash rapidly.

3.Install a jumper on either the hard open or the hard close input terminals. The motor will run for a few seconds and then stop. If the LED goes out the motor is learned. If the unit activates a limit before completing the learn or some other error occurs, the LED will go back to on continuously. If this happens, try learning while running in the opposite direction.

NOTE: It is important that the jumper is in constant contact while the gate is moving in learn mode.

FORCE CONTROL

Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force. On most operators this will be around the middle of the range.

NOTE: For LED location refer to illustration on previous page.

DIAGNOSTICS (LEDS AND CODES)

There are three diagnostic LEDs. Two red LEDs (OLS, CLS) are indicators for the open and close limits. The LEDs are illuminated when the limit switch contacts are closed.

The third amber LED (DIAG) is used to blink out diagnostic codes. The number is the count of the number of times the LED is on in an 8 second period. The LED is on for approximately 1/2 second and repeats every second until the number is reached. There will be a pause following each pulse cycle (1-6 pulses) to differentiate between the different diagnostic codes.

MOTOR LEARN BUTTON

Motor

Learn

Button (S3)

FORCE CONTROL

Force Control

Min

Max

LED Code

Diagnostic Meaning

Cleared By

Flashed

 

 

OFF

Normal operation

N/A

 

 

 

1

Single entrapment sensed

Control Input

 

 

 

2

Double entrapment

Hard Input*

 

 

 

3

Failed or no hall

Removal of

 

effect sensor

problem

 

 

 

4

Exceed maximum motor

Hard Input*

 

run time

 

 

 

 

5

Limit fault

Control Input

 

 

 

6

Loss of communications

Removal of

 

between master and

problem

 

second during run mode

 

 

 

 

On No

Motor not learned

Completion

Flash

 

of Motor Learn

 

 

Routine

*Hard inputs include open override, close override and stop inputs.