30 of 53 Doc 6001242 (01-20273) Rev C
There are 2 different ways to close the gate (entering or exiting):
1. Reclose Timer: When the Reclose Timer expires, gate closes automatically (Master or Slave).
2. Interrupt Loop; clearing the Inside Interrupt Loops cause the gates to close (Master or Slave).
NOTE: To ensure gate closure, set Reclose Timer =ON in both Master and Slave
INPUT CONNECTIONS: (for more details, refer to Part 2, Paragraph L, Connecting Input W iring)
Master and Slave units require their own separate inputs.
If Radio inputs are used in both units, each requires its own transmitter and entry code.
MASTER UNIT SWITCH S1 SETTINGS AND INPUTS
Gate
Type
SLIDE
ACTION
(Reclose)
TIMER RETRY ATG MASTER TRAP Operator
Inputs
Trap Unit
Optionn
Unit
Optionn
Unit
Optionn ON ON ON Unito
SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS
Trap Unit
Optionn
Unit
Optionn
Unit
Optionn No Effect OFF OFF Unito
n: Master and Slave units can have different Reclose Timer settings.
o: Inputs affect one gate operator only, so connect inputs s eparately to each gate operator.