
32 of 53 Doc 6001242 (01-20273) Rev C
• A continuous FIRE input in either gate opens both gates and holds them open.
• A continuous Manual STOP in either gate stops both gates.
There are 2 different ways to close the gate after entering or exiting:
1. Reclose Timer: When the Reclose Timer expires, the gates close automatically (Master or Slave).
2. ATG and Interrupt Loop: When ATG is ON, clearing the Inside Interrupt Loop causes the gate t o
close (Slave unit only).
INPUT CONNECTIONS: (for more details, refer to Part 2, Paragraph L, Connecting Input W iring)
MASTER UNIT SWITCH S1 SETTINGS AND INPUTS
Gate
Type
SLIDE
ACTION
(Reclose)
TIMER RETRY ATG MASTER TRAP Operator
Inputs
Tandem Unit
Optionn
Unit
Optionn
Unit
Optionn OFF ON ON o
SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS
Tandem Unit
Optionn
Unit
Optionn
Unit
Optionn
Unit
Option OFF OFF o
n: Master and Slave units can have diff erent settings.
o: Exit, Radio, Cycle, Fire, and Manual Stop inputs aff ect both gate operators, so connect inputs to one unit only.