POWER SWITCH SETTINGS

NOTE: To avoid the possibility of duplicating codes in adjacent systems, all transmitters and receivers should be re-coded prior to operation. Unless using maximum number of codes the following four codes should not be used:

Power Supply Selection Setting

The TriCode® receiver is factory set for 24 volt power input if 12 volt is required.

·All DIP Switches ON

·All DIP Switches OFF

·DIP Switches alternating ON/OFF

·DIP Switches alternating OFF/ON

Receivers should be installed at least 5' apart to avoid cross-talk. After completing installation, operate transmitter outside of building to make certain the chosen DIP switch setting does not operate with nearby garage door operators and/or security systems. If so, select another DIP switch setting and check the coded signal again. Repeat as necessary.

RECEIVER MOUNTING

Mount receiver to wall using #6 hardware (not provided). Hardware used will depend on mounting application. Refer to Figure 1 for receiver mounting hole locations.

Figure 1Back View

Remove back cover of receiver by removing screws. Set jumper to the 12 volt setting (Figure 1).

Mounting Holes

JUMPER

 

(P3)

 

 

24V

12V

 

P3

 

24V 12V

P3