Hold coupling nut and regulator
as shown for proper connection
to LP cylinder valve.
6.Turn the coupling nut clockwise and tighten to a full stop. The regulator will seal on the
NOTE:
If you cannot complete the connection, disconnect regulator and repeat steps 5 and 6. If you are still unable to complete the
connection, do not use this regulator!
Leak Testing Valves, Hose and Regulator
1.Turn all grill control knobs to OFF.
2.Be sure regulator is tightly connected to LP cylinder.
3.Completely open LP cylinder valve by turning hand wheel counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.
4.Brush soapy solution onto areas circled below.
DANGER
•Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.
WARNING |
•Outdoor gas appliance is not intended to be installed in or on a boat.
•Outdoor gas appliance is not intended to be installed in or on an RV.
•Never attempt to attach this grill to the
•Do not use grill until
•If a leak is detected at any time, STOP and call the fire department.
•If you cannot stop a gas leak, immediately close LPcylinder valve and call LP gas supplier or your fire department!
5.If “growing” bubbles appear, there is a leak. Close LP cylinder valve immediately and
6.Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.
6 • 463666508