Intimidator Spot 150 Service Maintenance Guide

Intimidator Spot 150 Service Maintenance Guide

Symptom(s)

Possible Solution(s)

Lamp is not illuminating

Clean the fixture regularly to avoid any such failure. This fixture is forced

convection cooled, which means that if the fans are kept clean and free of

 

 

debris, then proper cooling will be allowed to occur

 

Check the options in the display for Lamp function [on~off]. Also check the

 

DMX signal. It is possible to remotely turn off the lamp with a DMX controller.

 

Check to see if the lamp needs to be replaced. This is a wear item, and will

 

need to be checked and replaced on a regular basis of operation.

Breaker/Fuse keeps blowing

Check total load placed on the electrical circuit

 

Check for a short in the electrical wiring: internal and/or external

Device has no power

Check device’s fuse (internal)

 

 

Check for power on Mains

 

 

-Note: In the event of magnetic transformer failure, the unit can be sent in for

 

repair; however, a replacement part can be ordered directly from Chauvet

 

 

Part#: P140-IS150TRAN

Fixture is not responding to DMX

Check Control Panel settings for correct addressing

 

 

 

 

Check DMX cables

 

 

 

 

Check polarity switch settings on the controller

 

 

 

 

Check cable connections

 

 

 

 

 

Call service technician

 

 

 

 

-Note: In the event of Display/Master PCB failure, a replacement PCB can be

 

ordered directly from Chauvet

Part#: P170-IS150MAS

Loss of signal

Use only DMX cables

 

 

 

 

 

Install terminator

 

 

 

 

Note: Keep DMX cables separated from power cables or black lights

 

 

Pan/tilt movement, color, gobo

1 or more sensors may need to be adjusted or replaced. This may be either

reset problem

the optical sensor or the magnetic stopper sensor.

 

Note In the event of a sensor failure, a replacement sensor may be ordered

 

directly from Chauvet:

Part#: Magnetic Pan: P170-IS250PSS

 

 

Optical Pan: P170-IS250POS

 

 

Magnetic Tilt: P110-IS250TSS

 

 

Optical Tilt: P100-IS250TOS

 

 

Gobo: P100-IS150GWS

 

 

Gobo rotation: P100-IS150GRS

 

 

Color: P100-IS150CWS

The display backlight will not turn

There is an option in the control board that determines if the display turns off

off and stays lit

after 30 seconds of inactivity, or if the display stays lit indefinitely.

 

-See section “5-Display” in the onboard display “close”.

If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location on the following page.