Setup

Installation

ORI ENT AT IO N

This fixture is designed to achieve an Ingress Protection Rating of 54 only when the fixture’s base is attached to a level horizontal surface. The ART-575W can be mounted both upright and on a truss system.

Warnin g

It is important never to obstruct the fan or vents pathway.

When selecting installation location, take into consideration lamp replacement access and routine maintenance.

Safety cables should always be used.

The fixture must have a minimum of 1 meter distance from combustible materials.

126

Floor mount

FLOOR M OUNT ING

1)If connected, be sure to always disconnect from main power before installing fixture.

2)The ART-575W is constructed with mounting bracket/yoke.

3)Bolt fixture onto a leveled floor surface using floor mount holes and 3/8” diameter bolts.

T RUSS M OUNT ING

The ART-575W includes 3 clamp mounting brackets to which half- coupler pipe clamps can be bolted.

1)Verify the structure can hold 10 times the weight of all fixtures to-be installed.

2)Attach a minimum of two to three clamps where illustrated.

Clamp

Base