Arena™ Hazer 3 User Manual (Rev. 02) Page 11 of 16
5. T

ECHNICAL

I

NFORMATION

General Maintenance

Do not allow the fog machine to become contaminated. After every 40 hours of
continuous operation, it is recommended to run a cleaning solution composed of 80%
distilled water and 20% distilled vinegar through the system to prevent the
accumulation of particulate matter in the heating element.
The recommended cleaning regimen is as follows:
1. Empty all fog liquid from the machine.
2. Add cleaning solution to tank.
3. Plug unit in and allow it to warm up.
4. Run the unit in a well-ventilated area until the tank is almost empty. Do not
allow the pump to run dry.
5. Cleaning is now complete. Refill with fog liquid. Run the machine briefly to
clear any cleaning solution from the pump and heater.
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your
Arena™ Hazer 3. Make sure you use FCQ regularly to increase the life of your
product.

Storage

Before storing this product, run distilled water (not tap water) through the system as
described in the cleaning method above. This will help to avoid any particles
condensing inside the pump or heater.
It is strongly recommended to test-run the machine on a monthly basis in order to
achieve its best fogging condition.
Do not operate the machine without liquid at any time!