4. OPERATING INSTRUCTIONS

Navigating the Control Panel

Access control panel functions using the four panel buttons located directly underneath the LCD
Display. NOTE: The display will turn off after 30 seconds if no buttons are pushed.
MODE
/ESC
Button Function
<MODE/ESC> Used to access the menu or to scroll
through top-level menu items.
<UP> Scrolls through menu options in ascending
order
<DOWN> Scrolls through menu options in descending
order
<ENTER> Used to select and store the current menu
or option within a menu
UP
DOWN
ENTER
CONTROL PANEL

DMX Si

g

nal Indicato

r

The Control Panel LED Display shows the menu items you select from the menu map on page 13.
When a menu function is selected, the display will show immediately the first available option for the
selected menu function. To select a menu item, press <ENTER>.
Press the <MODE/ESC> button once to activate the control panel. Pressing the <MODE/ESC> button
again will scroll through the different top-level menu options available. Use the <UP> and <DOWN>
buttons to navigate the menu options. Press the <ENTER> button to access the menu function
currently displayed or to enable a menu option. To return to the previous option or menu without
changing the value, press the <MODE/ESC> button.

Intimidator Spot 2.0 HTI Manual 13 2007-01-24/09:36