Operation
Reset
Performance Power
Output Options
Manual Zoom Control
Master/Slave Mode
To reset the OVATION™
1.Go to the SET main level.
2.Select the REST programming level and then the display becomes blank. Enter the passcode as described in Passcode. After successfully entering the passcode, REST blinks on the display during the reset process.
3.OK appears on the display when finished.
The OVATION™
1.Go to the SET main level.
2.Select the PERF programming level.
3.Select from the following options:
∙Select LIVE to cool the LEDs by balancing the use of the fan and the power output level.
∙Select STDO to cool the LEDs by maintaining the use of the fan and limiting the power output level.
∙Select POWR to cool the LEDs by maintaining the use of the fan and allowing full power output.
The OVATION™
∙Locate the zoom adjustment knobs on either side of the OVATION™
The Master/Slave mode allows a single OVATION™
Configure the units as indicated below.
The Slaves:
1.Go to the RUN main level.
2.Select SLAV.
3.Connect the DMX input of the first slave to the DMX output of the master.
4.Connect the DMX input of the subsequent slaves to the DMX output of the previous slave.
5.Finish setting and connecting all the slaves.
The Master:
1.Go to the SET main level.
2.Select the MCON programming level.
3.Select MAST.
Note: If you select SELF, no DMX signals are sent to the slaves.
4.Make the master the first product in the DMX daisy chain.
5.Control the master using the DMX controller and the slaves will operate in unison.
Do not connect a DMX controller to the products configured for slave operation. The DMX controller may interfere with signals from the master.