RECEPTACLE DETAILS

RECEPTACLE DETAILS

The receptacles configurations shown in this section are for reference only. Each receptacle is not available on all generators.

NEMA 5-20R

NEMA L5-30R

NEMA L6-30R

NEMA L6-20R

125V - 20A

125V - 30A

250V - 30A

250V - 20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEMA 14-50R

NEMA L14-20R

NEMA L14-30R

125/250V - 50A

125/250V - 20A

125/250V - 30A

ENGINE LIMITATIONS ON GENERATOR PERFORMANCE

Generator ratings assume 60°F (20C) and Sea Level. Operation of your generator at temperatures above 60°F (20C) or above Sea Level will result in lower electrical output. Electrical output must be derated 2% for each 9°F above 60°F and 3 ½ % for each 1000 feet above mean sea level.

LOADING YOUR GENERATOR SET

WITH REFERENCE TO THE RECEPTACLE DETAILS SECTION, PLEASE REVIEW THE POWER RECEPTACLES FITTED TO YOUR GENERATOR. THE ACTUAL LOAD THAT MAY BE PULLED FROM EACH RECEPTACLE IS DRIVEN BY THE CIRCUIT BREAKER RATING AND THE GENERATOR RATING. ALL GENERATOR UNITS ARE EQUIPPED WITH A “PUSH TO RESET” CIRCUIT BREAKER.

DO NOT EXCEED THE INDIVIDUAL RECEPTACLE RATINGS AS SHOWN IN THE TABLE BELOW. DO NOT EXCEED THE TOTAL GENERATOR RATING SHOWN IN TABLE 2 PERFORMANCE SPECIFICATIONS.

AMPERAGE RATE TABLE

Model

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

SKU

120V Duplex

120V Duplex

120V GFCI

125/250V Twistlock

125V/250V Twistlock

38862

20Amps

20Amps

20Amps

N/A

N/A

38863

20Amps

20Amps

20Amps

N/A

15Amps

39408

20Amps

20Amps

20Amps

N/A

20Amps

39321

20Amps

20Amps

20Amps

N/A

20Amps

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS AND WIRING DIAGRAM(S) IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT; IN FACT THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. PARTS MAY CHANGE OR VARY FROM THOSE SHOWN.