9.If the low battery alarm is on all the time try these corrective measures: Recharge battery if in poor condition. Next, check the condition of the lighter cable plug and the socket. You may need to clean the socket.

10.If you are getting a low output voltage, try reducing the load to minimize watts. You may have overloaded the inverter. Reduce your load to 140 watts. Also, keep input voltage above 10.5 volts to maintain a constant flow of power.

11.If you are not getting any power output, turn the power switch Off, and On again, until the green power light comes on. Some automotive systems require that the ignition be turned on. Turn the ignition to the accessory position. Your devices may draw too much power to operate them. The inverter may be in thermal shutdown. Let it cool down and make sure there is adequate ventilation around the unit.