Chicago Electric 97677 manual Wet Vacuuming

Models: 97677

1 15
Download 15 pages 36.43 Kb
Page 10
Image 10

Wet Vacuuming:

1.Unlock the Right Latch (34) and Left Latch (59). Then remove the Upper

Cover (9).

(See Figure A, and Assy. Diagram.)

2.Snap the Foam Filter (85) over the Filter Cage (84). NOTE: The

Foam Filter must be flush with the underside of the Upper Cover (9).

(See Figure A.)

3.Replace the Upper Cover (9), and lock the Right Latch (34) and Left Latch (59).

(See Figure A, and Assy. Diagram.)

4.Attach the Suction Hose (50) to the Intake Port (49). (See Figure A.)

5.Extend the Telescopic Suction Tube (82), and attach it to the end of the Suction Hose (50). (See Figure A.)

6.Attach either the accessory Wet & Dry Brush (83), Crevice Nozzle (86), or Furniture Brush (87) to the end of the Telescopic Suction Tube (82).

(See Figure A.)

7.Plug the Power Cord (11) into the nearest 120 volt, grounded, electrical outlet.

8.Turn the Switch Knob (80) to its “ON” position to start the Wet/Dry Vacuum. (See Figure A.)

9.Adjust the air flow rate of the Vacuum

by sliding the Air Flow Adjusting Knob

(67) to the left or right.

(See Figure A.)

10.Guide the accessory Wet & Dry Brush (83), Crevice Nozzle (86), Furniture Brush (87) with slight pressure, slowly and evenly, over the dirty water. (See Figure A.)

11.IMPORTANT: The Wet/Dry Vacuum features Safety Float (63) which will automatically stops the vacuuming when the Tank (35) is full (as indicated when the Motor speed increases). If this happens, turn off the Switch Knob (80) and unplug the unit from its electrical outlet. Then position the Vacuum near a drain, and drain the dirty water using the Drain Hose (29). (See Figure A.)

12.When finished vacuuming, turn the Switch Knob (80) to its “OFF” position. Then unplug the Wet/Dry Vacuum from its electrical outlet.

(See Figure A.)

13.Position the Vacuum near a drain, and drain the dirty water using the Drain Hose (29). (See Figure A.)

14.Unlock the Right Latch (34) and Left Latch (59). Then remove the Upper

Cover (9).

(See Figure A, and Assy. Diagram.)

15.Remove the Foam Filter (85) from the Filter Cage (84). If necessary, the Foam Filter may be cleaned with running water. Then clean and dry the Tank (35) inside and out.

(See Figure A.)

16.Replace the Upper Cover (9), and lock the Right Latch (34) and Left Latch (59).

(See Figure A, and Assy. Diagram.)

17.Keep the accessories in the Vacuum’s built-in storage receptacles, and store the unit in a clean, dry, safe location out of reach of children and other unauthorized people.

REV 10c

SKU 97677

For technical questions, please call 1-800-444-3353.

Page 10

Page 10
Image 10