Chicago Pneumatic Auto Feed Drills & Tappers manual Control Blocks and Interfaces, Solenoid Valves

Models: Auto Feed Drills & Tappers

1 16
Download 16 pages 58.47 Kb
Page 8
Image 8

Control Blocks and Interfaces

Control Blocks

A1

Full Feature Control Block

A6

Simple Control Block

 

Part No. 436313

 

Part No. 103862

 

 

 

 

 

 

 

 

 

 

Air Connections

RAir Return Port – Connects to breather port in nose of tool to provide extra retract capability with heavy front end attachments (1/8” BSP)

ST

Start Button – For manual operation and set-up

1Remote Start Signal Port Pulse (M5)

SP

Manual Stop Button – Interrupts cycle and returns AFD to datum

PRemote Stop Signal Port – Requires external signal pulse for returning the unit to datum rest position (M5)

OAir inlet (1/4” BSP or 1/4” NPT)

MWork Cycle Complete Port – Used for sequence control with other AFD’s clamps, index tables, etc (positive at datum position) (M5)

ODepth Stop Signal Port – Used with external circuits such as dwell or pecking (1/8” BSP)

Retract rate adjustment control

Advance rate adjustment control

Feed rate adjustment control

FFeed port (1/8” BSP)

RN

Return port (1/8” BSP)

Electrical Connections

S1

Start solenoid

S2

Stop solenoid

SW1

Datum return (M8 x 1.00)

SW2

Depth position (M8 x 1.00)

Electrical Interfaces (not included with control blocks)

 

C10

Part No. 438223

C3

Part No. 104002

Solenoid Valves

 

Comprises :

 

Comprises :

ALL 24V DC

 

2 x M8 Proximity Switches PNP (NO)

 

2 x M8 Proximity Switches PNP (NO)

NC – Valve normally closed

 

2 x Plug-in Cables

 

2 x Plug-in Cables

NO – Valve normally open

 

2 x Solenoid Valves (NC)

C5

Part No. 104842

Proximity Switches

C11

Part No. 438233

 

Comprises :

All 10-30V DC

 

Comprises :

 

2 x M8 Proximity Switches NPN (NO)

NC – Normally closed

 

 

NO – Normally open

 

2 x M8 Proximity Switches PNP (NO)

 

2 x Plug-in Cables

 

2 x Plug-in Cables

 

 

 

 

1 x Solenoid Valve (NC)

 

 

 

 

1 x Solenoid Valve (NO)

 

 

 

C12

Part No. 438243

 

 

 

 

Comprises :

 

 

 

 

2 x M8 Proximity Switches NPN (NO)

 

 

 

 

2 x Plug-in Cables

 

 

 

 

2 x Solenoid Valve (NC)

 

 

 

AFD60 / AFT60 Control Block (Supplied fitted)

Air connection as above except M port which is negative at datum.

To invert signal use kit

Electrical Inputs and Outputs

24VD.C. Switched Red OV. Common Black 24VD.C. Switched Green Switch Yellow

Switch Common White Switch Blue

Part No. 104822

Electrical Interface

Part No. 79532

24V DC Comprises:

2 metre cable Adaptor and O ring Interface block

8

Page 8
Image 8
Chicago Pneumatic Auto Feed Drills & Tappers Control Blocks and Interfaces, AFD60 / AFT60 Control Block Supplied fitted