MODEL NUMBER DESCRIPTION

TABLE 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAF-6

B

2

05

11

01

A1

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to

CCAS-8

 

 

 

 

 

 

 

 

 

 

Code

Control Options (Factory Installed)

Wiring

Diagram

 

 

 

 

 

 

 

 

 

 

 

 

00

= No Optional Control

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A1

= Built-in SP tamperproof thermostat 120 - 277V

 

C

 

 

 

 

 

 

 

 

 

 

 

 

A2

= Built-in DP tamperproof thermostat 120 - 277V

 

E

 

 

 

 

 

 

 

 

 

 

 

 

F1

= Built-in SP adjustable thermostat 120 - 277V

 

C

 

 

 

 

 

 

 

 

 

 

 

 

F2

= Built-in DP adjustable thermostat 120 - 277V

 

E

 

 

 

 

 

 

 

 

 

 

 

 

A4

= Built-in 24V low voltage relay 120 - 277V

 

D

 

 

 

 

 

 

 

 

 

 

 

 

A5

= Built-in 24V low voltage relay and transformer 120 - 277V

 

F

 

 

 

 

 

 

 

 

 

 

 

 

A8

= Built-in disconnect switch, rated 277V@20A

 

B

 

 

 

 

 

 

 

 

 

 

 

 

B1

= Built-in SP tamperproof thermostat and disconnect

 

G

 

 

 

 

 

 

 

 

 

 

 

 

B2

= Built-in DP tamperproof thermostat and disconnect

 

H

 

 

 

 

 

 

 

 

 

 

 

 

F3

= Built-in SP adjustable thermostat and disconnect

 

G

 

 

 

 

 

 

 

 

 

 

 

 

F4

= Built-in DP adjustable thermostat and disconnect

 

H

 

 

 

 

 

 

 

 

 

 

 

 

D1

= Built-in low voltage relay and disconnect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D2

= Built-in low voltage transformer and disconnect

 

 

 

 

 

 

 

 

 

 

 

 

Painted

Anodized

 

 

 

 

 

 

 

 

 

 

 

 

68 = Almond

07

= Bronze

 

 

 

 

 

 

 

 

 

 

 

 

02 = White

10

= Clear

 

 

 

 

 

 

 

 

 

 

Code

Voltage/Phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11 = 120/1 21 = 208/1 31 = 240/1

41 = 277/1

 

 

 

 

 

 

 

 

Code

Wattage (See Table)

 

 

 

 

 

 

 

 

 

 

Code

Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = 2 ft.

3 = 3 ft.

4 = 4 ft.

5 = 5 ft. 6 = 6 ft.

7 = 7 ft.

8 = 8 ft. 9 = 9 ft. 10 = 10 ft.

 

 

 

 

Code Inlet Location

 

 

 

 

 

 

 

 

 

 

 

 

F = Front

 

B = Bottom

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL

This document explains the correct procedure for the installa- tion and safe operation of all models of Draft Barrier and Pedestal Mounted Heaters.

Draft Barrier Heating Systems are designed to be installed in accordance with the National Electrical Code and with local codes by a qualified person.

General Information —

Draft Barriers and Pedestal Mounted Heaters are intended for wall, sill or floor mounting.

The heaters are designed so that they may be used as an indi- vidual cabinet convector, in a wall-to-wall configuration or as an end-to-end continuous perimeter room heating system.

Draft Barrier heating systems are supported by a wide selec- tion of controls and accessories designed to solve any heating requirement.

Before You Unpack —

1.Make certain that the number of cartons received agrees with the Bill of Lading, Packing List and original order. Also check that the correct style (Model) and color have been shipped.

2.Every heater is carefully inspected and shipped with a clear Bill of Lading.

Obvious external and/or concealed damage must be reported to the carrier for remedy.

WARNING: Hazard of Fire

1.DO NOT INSTALL HEATERS AGAINST ANY HIGH- LY COMBUSTIBLE SURFACES SUCH AS LOW DENSITY CELLULOSE FIBRE.

2.DO NOT LOCATE HEATER BELOW ELECTRICAL CONVENIENCE RECEPTACLES.

3.DO NOT STORE OR USE GASOLINE OR FLAMMA- BLE LIQUIDS IN THE VICINITY OF THE HEATERS.

WARNING: Hazard of Fire. The normal operating temperatures of cabinet convectors are relatively high and proper operation requires free circulation

of room air through the heating element. Bottom air inlet heaters must be mounted with minimum of 2” from finished floor.

WARNING: Hazard of Fire. Keep electrical cords, drapes, rugs and other furnishings away from the heater.

WARNING: Hazard of Fire. Furniture must be placed no closer than four inches from the heater (see Figure 1)

WARNING: Hazard of Fire. Drapes must clear the top of heater by at least twelve inches; or, if floor length drapes are used, they must clear the fin- ished floor by three inches and the minimum clear- ance from the back fold to the front cover should be at least four inches (see Figure 1)

WARNING: Hazard of Fire. When the floor is to be finished in carpet, allow clearance under the heaters and corners for carpet installation. Bottom air inlet heaters are to be mounted a minimum of 2” from the finished floor.

WARNING: Hazard of Fire. Rugs may be placed up to a heater provided that they are not of a thick- ness that would block the air-intake. Bottom air inlet heaters are to be mounted a minimum of 2” from the finished floor.

Figure 1: Furniture & Drapes

Page 2
Image 2
Chromalox CAF-6, CCAS-8 specifications Model Number Description, General Information, Before You Unpack

CCAS-8, CAF-6 specifications

Chromalox CAF-6 and CCAS-8 are innovative products designed to enhance thermal management in industrial applications. These heating solutions are particularly effective in environments that require precise temperature control, ensuring optimal performance and safety.

The Chromalox CAF-6 is a powerful heating element engineered to provide consistent and efficient heat transfer. One of its key features is the advanced construction that allows it to withstand high temperatures while maintaining reliability. The CAF-6 utilizes a durable alloy that offers excellent thermal conductivity, ensuring that heat is distributed evenly. This characteristic minimizes the risk of hotspots and enhances equipment longevity.

On the other hand, the CCAS-8 is designed as a flexible heating solution, making it suitable for a wide range of applications. Its versatility allows for easy installation in tight spaces, while still delivering high performance. The CCAS-8 incorporates cutting-edge technology such as advanced microprocessor controls, which allow for precise temperature monitoring and adjustments. This ensures that processes are kept within specified temperature ranges, reducing the risk of overheating or underheating.

Both the CAF-6 and CCAS-8 feature robust safety mechanisms. They include over-temperature protection, which automatically shuts off the heating function if temperatures exceed safe limits, thereby preventing equipment damage and enhancing user safety. Additionally, both products are designed to be highly energy-efficient, contributing to lower operational costs and minimizing environmental impact.

Another essential characteristic of Chromalox heating products is their adaptability to different industrial needs. They can be customized according to specific operational requirements, ensuring that customers receive a heating solution tailored to their processes. This adaptability makes the CAF-6 and CCAS-8 ideal for industries such as oil and gas, food processing, and pharmaceuticals, where precise temperature control is crucial.

In conclusion, the Chromalox CAF-6 and CCAS-8 stand out in the realm of industrial heating solutions due to their advanced features, reliable performance, and adaptability. With these products, businesses can achieve efficient thermal management that meets both operational demands and safety standards. Whether used individually or in conjunction, they exemplify the commitment of Chromalox to innovation and quality in heat management technology.