MOUNTING

WARNING: Hazard of Electric Shock. Disconnect all power before installing heater.

1.Locate on vertical wall with length of heater positioned hori- zontally.

2.When selecting a mounting location, the following minimum distances must be observed to insure proper operation.

A.Six (6”) inches from bottom of heater to floor.

B.One (1”) inch from wall or other obstruction to the right or left side of heater.

3.Do not mount heater in a recess, since such mounting interferes with free air circulation, increases temperatures and prevents proper thermostat operation.

4.Mount the rear panel assembly of the heater to the wall using the 11/32” dia. holes (bolts to be supplied by customer).

5.Install the perforated cover by hooking the top edge of the cover over the top edge of rear panel.

6.Attach the bottom lip of the perforated cover to the wall using the 1/4-20x1” tamper proof screws.

7.On lower cover assembly connect wires T1-T1 and T2-T2 with wire nuts provided. Install cover assembly with (2) 10-32x1/2and (1) 1/4-20x1” tamper proof screws. Use special magnetic bits provided. (Use standard 5/16 socket or variable speed drill when attaching screws.

8.Wire power lines to pigtail leads marked L1 and L2. Connect ground wire to the green pigtail lead.

9.Adjust thermostat to the desired setting. Install top access cover with (4) 10-32x1/2tamper proof screws using spanner tool bits provided.

WIRING

WARNING: Hazard of Electrical Shock. Any installa- tion involving electric heaters must be grounded to earth to eliminate shock hazard.

Note: Electrical wiring is to be in accordance with National Electrical Code and local codes using at least 75°C (167°) type RH, THW or equivalent insulated wire.

1.Electrical wiring must be brought into heater through 13/32” dia. hole located in the rear panel.

2.Grounding conductor with green insulation must be connected to the green pigtail lead.

3.Make the proper connections using the appropriate wiring dia- gram below. Use diagram A for 120 and 277V heaters and use diagram B for 208 and 240V heaters. These diagrams apply to all size heaters.

Wiring Diagram A

White Wire

Heating

Element

T2

T1

AutoT'Stat

Cutout

Black Wire

T2

L2

T1

L1

Disconnect

Switch

Wire Nuts

Common

120 277V

Power

Circuit

Grd (Green)

Wiring Diagram B

Heating

Element

 

T2

 

T1

Auto

Double

Cutout

Pole

 

 

T'Stat

T2

L2

T1

L1

Disconnect

Switch

Wire Nuts

208240V

Power

Circuit

Grd (Green)

Page 2
Image 2
Chromalox ICH-38075, ICH-60125, ICH-72100, ICH-18025, ICH-28050, ICH-45100 specifications Mounting, Wiring

ICH-45100, ICH-28050, ICH-18025, ICH-38075, ICH-72100 specifications

Chromalox, a leader in thermal technologies, has developed a series of industrial heaters known as the ICH series, which includes the ICH-18025, ICH-60125, ICH-28050, ICH-38075, and ICH-72100 models. These heaters are designed for a variety of applications, providing efficient and reliable heat to meet diverse industrial needs.

The ICH-18025 is a compact and powerful heating solution, offering a wattage output that makes it suitable for small to medium-sized applications. Its design emphasizes energy efficiency, with built-in thermostatic controls that enable precise temperature regulation. This model is particularly ideal for environments that require consistent heat without significant energy expenditure.

Next in line is the ICH-60125, which features enhanced watt density, making it capable of heating larger volumes of material swiftly. The ICH-60125 is designed with high-quality components that contribute to its durability and longevity. It includes advanced safety features, such as over-temperature shut-off, ensuring safe operation even in demanding conditions.

The ICH-28050 heater offers a balance between size and power, presenting users with versatility in application. Its robust construction and reliable performance make it suitable for applications in food processing, plastics manufacturing, and chemical processing. The model is designed to minimize heat loss, thereby optimizing energy consumption while maximizing output.

With the ICH-38075, users benefit from a higher capacity heater that is great for applications requiring large-scale heat generation. This model incorporates advanced heating technology, ensuring uniform heat distribution and quick responsiveness to temperature changes. The ICH-38075 is ideal for heavy-duty applications where efficiency and reliability are crucial.

Finally, the ICH-72100 stands out as a high-capacity industrial heater capable of handling the most demanding environments. With enhanced control options and the ability to manage significant heating loads, this model is perfect for industries such as oil and gas, pharmaceuticals, and heavy manufacturing. Its integration of smart technology means it can be monitored and controlled remotely, providing users with flexibility and ease of operation.

Each model in the Chromalox ICH series is engineered with thermal efficiency, safety, and performance in mind. The heaters are designed to withstand harsh conditions while providing reliable service, making them a top choice for industrial heating solutions. With a focus on innovation and quality, Chromalox continues to set the standard in thermal technologies for diverse industries.