GENERAL
The Chromalox Type
Its aluminum construction and consequent light weight make it ideal for suspension with the No. 2 size chain and “S” hooks pro- vided. Aluminum reflector housing requires no painting and is eas- ily cleaned.
WARNING: Users should install adequate controls and safety devices with their electric heating equipment. Where the consequences of failure may be severe,
MOUNTING
WARNING: Hazard of Electric Shock. Disconnect all power before installing heater.
Minimum mounting distances for all heaters are as shown in Figures A and B. Using the No. 2 size chain and “S” hooks fur- nished, heaters are to be suspended in a horizontal position only.
NOTE: For proper balance, it is suggested that each of the four corners be individually suspended (rather than gathered into a common center mounting point, see Figure C and D).
| Ceiling | |
| 4" Min. | |
Wall | 14" | |
Min. | ||
| ||
| 72" Min. | |
| Floor |
Figure A
Wall
9" Min.
Wall | 14" |
| Min. |
Figure B
Conduit
Furnished by
Installer
Figure C (Right Way)
Figure D (Wrong Way)
WIRING
WARNING: Hazard of Electric Shock. Any installation involving electric heaters must be effectively grounded in accordance with the National Electrical Code to eliminate shock hazard.
Electric wiring to heater must be installed in accordance with
Table B — Wiring Diagram
the National Electrical Code and with local codes by a qualified person. WARNING: Use copper conductors only.
WARNING: To prevent electrical wiring problems due to overheating, route wiring conduit to avoid contact with reflector housing.
|
| 1 Phase |
|
| 3 Phase |
|
Model | 208V | 240V | 480V | 208V | 240V | 480V |
| Fig. | Fig. | Fig. | Fig. | Fig. | Fig. |
1 | ||||||
1 | ||||||
1 | ||||||
2 | ||||||
2 | ||||||
2 | ||||||
3 | 4 | |||||