5
Installing the CTX2500 Card in the Cisco ONS 15310-MA
78-17333-01
Install the CTX2500 Cards

CRAFT Port

An EIA/TIA-232 craft interface is provided and is used for TL1 provisioning.
The craft interface is set to 9600 baud, no parity, and 1 stop bit by default.

Nonvolatile Memory

The ONS 15310-MA nonvolatile memory has the following specifications:
128 MB, Compact Flash card
Install the CTX2500 Cards
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flowof cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement 1029
Warning
During this procedure, wear grounding wrist straps to avoid electrostatic discharge (ESD) damage to
the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock
yourself. Statement 94
Warning
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100
mm could pose an eye hazard. Statement 1056
Warning
Class I (CDRH) and Class 1M (IEC) laser products. Statement 1055
Warning
Use of controls, adjustments, or performing procedures other than those specified may result in
hazardous radiation exposure. Statement 1057
Caution Do not install a CTX2500 card in an ONS 15310-MA if the ambient temperature exceeds 149 degrees F
(65 degrees C).
Caution Always use the supplied ESD wristband when working with a powered ONS 15310-MA. Plug the
wristband cable into either of the ESD jacks, on the far left and right faceplates in the shelf.