6Rack-Mounting
This section covers basic
Catalyst
Equipment That You Supply
You need a Phillips screwdriver to
Before You Begin
Before installing the switch, verify that these guidelines are met:
•Clearance to front and rear panels is such that
–
–Access to ports is sufficient for unrestricted cabling.
•Make sure that there is access to the rear of the rack if you are planning to stack the switches or connect the RPS 2300. If you do not have access to the rear panel, make that sure you cable the switches before you
•If you have the optional
•AC power cord can reach from the AC power outlet to the connector on the switch rear panel.
•Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting fixtures. Make sure the cabling is safely away from other devices that might damage the cables.
•Airflow around the switch and through the vents is unrestricted.
•Temperature around the unit does not exceed 113°F (45°C). If the switch is installed in a closed or multirack assembly, the temperature around it might be greater than normal room temperature.
•For copper connections on Ethernet ports, cable lengths from the switch to connected devices can be up to 328 feet (100 meters).
•For cable lengths for X2 transceiver modules and