If one power supply is installed in the chassis, but the other power supply slot is empty, a blank filler
panel should be used to cover the empty slot. Figure 1-31 shows a blank power supply filler panel.
Figure 1-31 Blank Power Supply Filler Panel
Fan Module
The Cisco Nexus 5010 switch has slots for two fans modules. Each fan module houses six fans. The
combination of 6-fans per module and 2-modules provides the switch with a total of 12-fans.Figure 1-32
shows the fan module.
Power supply warning events where the power supply
continues to operate. These events include high
temperature, high power, and slow fan.
Off 1 Hz Blinking
AC present, 3.3 voltage standby (VSB) on, and the power
supply unit is off.
1 Hz blinking Off
Power supply on and OK. On Off
Table 1-5 Power Supply LED Descriptions (continued)
Power Supply Condition Power LED Status Fail LED Status