1-60
Cisco 7200 VXR Installation and Configuration Guide
OL-5013-08
Chapter1 Cisco 7200 VXR Product Overview
Functional Overview
Table1-34 NPE-G2Processor-Monitored Temperature Thresholds
NPE-G21
1. With an I/O controller installed.
Low Warning High Warning Shutdown
NPE inlet 111 F (44 C) 138 F (59 C) 176oF (80oC)
NPE outlet 120 F (49 C) 147 F (64 C) 183 F (84 C)
I/O controller inlet 105 F (41 C) 132 F (56 C) 168 F (76 C)
I/O controller outlet 107 F (42 C) 134 F (57 C) 170 F (77 C)
CPU Die 194 F (90 C) 221 F (105 C) 230 F (110 C)
Table1-35 NPE-G1Processor-Monitored Temperature Thresholds
NPE-G11
1. With an I/O controller installed.
Low Warning High Warning Shutdown
NPE inlet 111 F (44 C) 138 F (59 C) 176F (80 C)
NPE outlet 120 F (49 C) 147 F (64 C) 183 F (84 C)
I/O controller inlet 105 F (41 C) 132 F (56 C) 168F (76 C)
I/O controller outlet 107 F (42 C) 134F (57 C) 170 F (77 C)
Table1-36 Typical Processor-Monitored Temperature Thresholds
Parameter High Warning High Critical Shutdown
NPE-175, NPE-225, NPE-300,
NPE-400, NSE-1
Chassis inlet 104 F (40 C) 122 F (50 C)
Chassis outlet 1 109 F (43 C) 127F (53 C) 136 F (58 C)
Chassis outlet 2 109 F (43 C) 127F (53 C)
Chassis outlet 3 122 F (50 C) 140F (60 C) 149 F (65 C)
NPE-100 or NPE-200
Chassis inlet 104 F (40 C) 122 F (50 C)
Chassis outlet 1 109 F (43 C) 127F (53 C) 136 F (58 C)
Chassis outlet 2 167 F (75 C) 167F (75 C)
Chassis outlet 3 122 F (50 C) 140F (60 C) 149 F (65 C)
NPE-150
Chassis inlet 104 F (40 C) 122 F (50 C)
Chassis outlet 1 109 F (43 C) 127F (53 C) 136 F (58 C)
Chassis outlet 2 167 F (75 C) 167F (75 C)
Chassis outlet 3 131 F (55 C) 149F (65 C) 158 F (70 C)