Image 2

Chapter 4 Storage/Control I/O Module

Description

Total Current

+5 VDC

0.9A

0.85A

 

+12 VDC

1.1A

.22A

Total Power

+.5 VDC

7.7 Watts

 

 

+12 VDC

6.89 Watts

 

Operating Temperature

10 to 40°C (50 to 104°F)

 

Relative Humidity

20 to 80% (noncondensing)

 

Physical Dimensions

Height:

14.4 inch (36.6 cm)

 

 

Depth:

5.6 inch (14.2 cm)

 

 

Width:

1.6 inch (4.1 cm)

 

Description

The Storage I/O Module is two card slots wide and slides into the back of the VCO system where it plugs into the control midplane. All outside connections are mounted on the faceplate of the module. All internal connectors are mounted on the board itself for easy access to system internals (for example, SCSI and Ethernet).

The VCO/4K system hard drive is mounted on the upper portion of the I/O Module. The board is built to accommodate a 3.5-inch hard drive. Physical mounting points are provided for the hard drive as well as a 50-pin SCSI interface to the system controller. There is also a provision for an external SCSI connection on the front panel. The SCSI connection is reserved for future use.