5.3 Manual Setting of Memory Switch

Memory switches can be set manually or by a command. For manual setting, refer to the next page.

The function of each memory switch is shown in the following table. (The white-on-black characters are factory setting.)

Switch No.

 

Setting

 

 

 

 

 

 

0 (OFF)

 

1 (ON)

Memory SW1-1

 

Power ON Info

 

 

 

 

 

 

 

 

Valid

 

 

 

 

 

Not send

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1-2

 

Buffer Size

 

 

 

 

 

4k bytes

 

 

 

45 bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1-3

 

Busy Condition

 

 

 

 

 

 

Full/Err

 

 

 

 

 

 

Full

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1-4

 

Receive Error

 

 

 

 

 

Print "?"

 

 

 

No Print

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1-5

 

CR mode

 

 

 

 

 

 

Ignored

 

 

 

 

 

LF

SW1-6

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1-7

 

DSR Signal

 

 

 

 

 

 

 

Invalid

 

 

 

 

 

Valid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1-8

 

Init Signal

 

 

 

 

 

 

 

Invalid

 

 

 

 

 

Valid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Memory SW2-1

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-2

 

Auto Cutter

 

 

 

 

 

 

 

Invalid

 

 

 

Valid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-3

 

Spool Print

 

 

 

 

 

 

 

Invalid

 

 

 

 

Valid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-4

 

Full Col Print

 

 

 

 

LineFeed

 

 

WaitData

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-5

 

Resume aft PE

 

 

 

 

 

 

 

 

 

Next

 

 

 

 

Top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-6

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-7

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-8

 

PNE Sensor

 

 

 

 

 

 

 

 

Valid

 

 

Invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Memory SW3-1

 

Resum Cttr Err

 

 

 

 

 

 

 

 

Valid

 

 

Invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3-2

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3-3

 

Parallel 31 Pin

 

 

 

 

 

 

 

 

Valid

 

 

Invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3-4

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3-5

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3-6

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3-7

 

CBM1000 Mode

 

 

 

 

 

 

 

Invalid

 

 

 

 

 

 

 

 

 

Valid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3-8

 

Resum Open Err

 

 

 

 

 

 

 

 

Close

 

 

 

 

 

Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Memory SW4-1

*M

P. Length Set

 

Auto Measure

 

 

Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-2

*M

Power on TOF

 

 

 

 

 

 

 

Invalid

 

 

 

 

 

 

 

 

 

Valid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-3

 

Feed&Cut at TOF

 

 

 

 

 

 

 

Invalid

 

 

 

Valid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-4

*L

Paper Select *1

 

 

Thermal Roll

 

BM.P / Lbl.P

*4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-5

*L

Position detect *2

 

 

 

Black Mark

 

 

Label

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-4

*M

Paper Select *1

 

 

Thermal Roll

 

 

 

 

BM.P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-5

*M

Position detect *2

 

 

 

Black Mark

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-6

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-7

 

Reserved

 

 

 

 

 

 

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4-8

*3

Prtial Only

 

 

 

 

 

 

 

Invalid

 

 

 

Valid

 

 

 

 

Notes:

*1: The factory setting of "Paper Select" will be different, depending on the model classfication.

*2: In the case of selecting the thermal roll with the SW4-4, the SW4-5 will not be available. The SW4-5 will be set to "Black Mark" status for the Black Mark version printer.

*3: In the label mode (with memory switches SW4-4 and SW4-5 set to ON), full cutting is used for paper regardless of the setting of memory switch SW4-8.

*4: When printing on label paper, printing columns of 660 dots is not usable. Memory switch SW2-8 is not usable with label paper.

— 29 —