Property

AutoDisable

BinaryConversion

CapPowerReporting

CapstatisticsReporting

CapUpdateStatistics

CheckHealthText

Claimed

DataCount

DataEventEnabled

DeviceEnabled

FreezeEvents

OpenResult

OutputID

PowerNotify

PowerState

ResultCode

ResultCodeExtended

State

ControlObjectDescripti on

ControlObjectVersion

ServiceObjectDescripti on

ServiceObjectVersion

Notes

Not applicable with OPOSPrinter

(Refer1to BinaryConversion in 2.6

POS Printer Service Object and Precautions.)

Not applicable with OPOSPrinter

Not applicable with OPOSPrinter

(Refer111to OutPutID property/ OutputCompleteEvent event in 2.6 POS Printer Service Object and Precautions.)

(Refer1to ResultCode/ ResultCodeExtended Property in

2.6POS Printer Service Object and Precautions.)

(Refer1to ResultCode/ ResultCodeExtended Property in

2.6POS Printer Service Object and Precautions.)

Attribu

te

R/W

R/W

R

R

R

R

R

R

R/W

R/W

R/W

R

R

R/W

R

R

R

R

R

R

R

R

×

{

{

×

×

{

{

×

×

{

{

{

{

{

{

{

{

{

{

{

{

{

Supporting status

(CT-S300_*/ CT-S 310_*) Not supported OPOS_BC_NONE (Default value)

OPOS_BC_NIBBLE

OPOS_BC_DECIMAL

At the connection of parallel or USB I/F

OPOS_PR_STANDARD

At the connection of serial I/F

OPOS_PR_NONE FALSE

FALSE

External HCheck: Successful ClaimeDevice True ReleaseDevice False

Not applied because no input device is used. Not applied because no input device is used. TRUEDataEvent notified

False: DataEvent not notified TRUEEvent notification disabled FALSE: Event notification enabled

In other than OPOS_SUCCESS, refer to OpenResult properties in “OPENPOS FOR OLE APPLICATION PROGRAMMER’S GUIDE Japanese-edition Specification Version 1.8”. Increment (+1)

OPOS_PN_DISABLE

(Power notification is not supplied.)

OPOS_PN_ENABLE

(Information on power notification is supplied.)

*Always OPOS_PN_DISABLE at the connection of serial I/F

Online and Ready state OPOS_ONLINE(2001)

Not Ready state OPOS_PS_OFFLINE(2003)

At the connection of serial I/F

OPOS_PS_UNKNOWN

In other than OPOS_SUCCESS, refer to ResulCode properties in “OPENPOS FOR OLE APPLICATION PROGRAMMER’S GUIDE Japanese-edition Specification Version 1.8”.

In other than OPOSIDLE, refer to State properties in “OPENPOS FOR OLE APPLICATION PROGRAMMER’S GUIDE Japanese-edition Specification Version 1.8”. 1.8***

1.8***

CITIZEN Service Object for Thermal Printers ver *.**.**

1******