iDP-3535 User’s Manual

6-3 Description of Input / Output Signals

1. Input / Output Signals

Input Signals (To Printer)

DATA 1

: 8 bit signal (Positive logic)

DATA 2

: 8 bit signal (Positive logic)

DATA 3

: 8 bit signal (Positive logic)

DATA 4

: 8 bit signal (Positive logic)

DATA 5

: 8 bit signal (Positive logic)

DATA 6

: 8 bit signal (Positive logic)

DATA 7

: 8 bit signal (Positive logic)

DATA 8

: 8 bit signal (Positive logic)

STB

: A strobe signal for reading in 8 bit data. (Negative logic)

RESET : RESET signal. (Negative logic)

Output Signals (From Printer)

ACK

: This is pulse signal for requesting 8 bit data, issued at the end of a BUSY signal. (Negative logic)

BUSY

 

: This signal indicated that your printer is in a BUSY state. New data should be input when this

 

 

signal is “LOW”. (Positive logic)

FAULT

: When your printer is in an alarm state, this signal is “LOW”. At this time, all control circuit of

 

 

your printer are interrupted. (Negative logic)

CITIZEN

22/38

Page 22
Image 22
Citizen Systems iDP-3535 user manual Data, Ack