D8 |
|
|
|
|
|
| D1 | |
0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
BEL (07) H
This command generates a drive pulse for first drawer based on the condition of drive pulse duration setting command.
This command is stored in the buffer and is performed when it is received from buffered queue.
D8 |
|
|
|
|
|
| D1 | |
0 | 0 | 0 | 1 | 1 | 1 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
FS(1C) H This command generates a drive pulse for first drawer based on the condition of drive pulse duration setting command.
This command is performed when the printer receiver it.
D8 |
|
|
|
|
|
| D1 | |
0 | 0 | 0 | 1 | 1 | 1 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
SUB (1A) H This command generates a drive pulse for second drawer. And drive pulse duration is fixed at 200 ms ON + 200 ms OFF.
This command is performed when printer receive it.
Remarks: First drawer and second drawer cannot be driven at the same time.