iDP-3540/41 User’s Manual

12-2-22. First Drawer Drive Command

D8

 

 

 

 

 

 

D1

0

0

0

0

0

1

1

1

 

 

 

 

 

 

 

 

 

 

BEL (07) H

This command generates a drive pulse for first drawer based on the condition of drive pulse duration setting command.

This command is stored in the buffer and is performed when it is received from buffered queue.

12-2-23. First Drawer Quick Drive Command

D8

 

 

 

 

 

 

D1

0

0

0

1

1

1

0

0

 

 

 

 

 

 

 

 

 

 

FS(1C) H This command generates a drive pulse for first drawer based on the condition of drive pulse duration setting command.

This command is performed when the printer receiver it.

12-2-24. Second Drawer Derive Command

D8

 

 

 

 

 

 

D1

0

0

0

1

1

1

0

0

 

 

 

 

 

 

 

 

 

 

SUB (1A) H This command generates a drive pulse for second drawer. And drive pulse duration is fixed at 200 ms ON + 200 ms OFF.

This command is performed when printer receive it.

Remarks: First drawer and second drawer cannot be driven at the same time.

CITIZEN

42/48

Page 42
Image 42
Citizen Systems iDP-3540, 3541 user manual 42/48