Maintenance
WARNING: Maintenance and repairs must be done by authorized personnel only.
WARNING: Always empty the solution tank and recovery tank before doing any maintenance.
WARNING: Keep all fasteners tight.
These Maintenance Procedures Must Be Done Every Day
Keep the machine clean, it will need fewer repairs and have longer life.
Do These Procedures When You Begin Your Work Period
1.Turn off key switch.
2.Disconnect AC power from battery charger (fol- low charger instructions).
2.Disconnect the plug on the battery charger from the battery pack connector.
3.Join the connector from the batteries to the control panel cable connection. See figure 22.
4.Make sure the Screen filter over the vacuum motor is clean and in position. See figure 24.
5.Make sure the recovery tank lid is on correctly. See figure 23, Item A.
6.Makesure thevalve on the recovery drain hoseis clean. Tightly close the valve.
7.Make sure the brushes/pads are in position and installed correctly.
8.Make sure brush housings and skirts are in position on the brush head.
9.Check the installation of the squeegee and squeegee hose.
10.Makesurethesolutiondrain/levelindicatorhose is secure on the storage mount on the rear of the machine.
Figure 22
A
Figure 23
Figure 24
Clarke® Operator's Manual - Encore S30/L30 | Page |